How should the boiler grate be monitored and maintained? What methods are available? What checks should be done before using the boiler grate?
Release Time:
May 25,2022
There are different operating methods for the boiler grate during operation, but from the current situation, we can see how to operate it effectively. Most people probably do not understand how to monitor and maintain the boiler grate during the operation process.

Monitoring is required during the operation of the boiler grate. In the actual monitoring process, all fans, oil pumps, or water pumps of the boiler grate should be monitored. However, during the monitoring process, the entire monitoring should be conducted using the method of one look, two cleanings, and three touches. In this case, effective measures will be taken to handle any abnormal situations involving the grate plate, boiler grate, boiler flue hood, economizer pipes, chain grate factory, and boiler parts foundry. If necessary, stop operation and then conduct inspections. Do not be careless. At the same time, manufacture automatic control devices. Regularly check the position of all oils. If the oil level of the boiler grate is found to be too low and cannot last for two hours, the fuel personnel must be notified in advance to inject new fuel.
The operation of water treatment equipment can be regularly checked during the actual operation of the boiler grate. Regardless of whether the ion exchange in the equipment has failed, backwashing must be performed regularly.
Monitor the flue gas temperature of the boiler grate. Generally, the flue gas temperature of these boilers is relatively low, but it will gradually increase with the extension of operating time. If these changes exceed 20, the boiler grate must choose an appropriate time to stop ash cleaning. If this phenomenon occurs frequently, the system must be checked for normality. If the oil pressure is too low and the oil temperature is relatively low, it may lead to poor atomization. Alternatively, if the air-oil ratio is incorrect, it may cause a lack of oxygen in the oil-gas co-firing.
How to effectively maintain the boiler grate during use, in addition to monitoring all equipment, regular sampling and testing are also required. The testing personnel should determine the quantity and frequency of relevant wastewater discharge, and detailed records of testing and wastewater discharge can be tested through automatic control.
The items to be checked before using the boiler grate include: The continuous running time of the boiler grate during cold trial operation should not be less than 8 hours. The cold trial operation should ensure that the small gap between the side sealing block and the side sealing angle steel is not less than 4mm. The distance between the two ends of the furnace long pin and the side plates of the grate should be kept equal at the sprocket shaft. If friction is found between one end of the chain grate and the side plate, it can be struck with a hammer at the long waist hole. The distances at both ends of the grate, boiler grate, boiler flue hood, economizer pipes, and chain grate factory should be kept equal, and the boiler grate should not have serious unilateral tilt.
The ignition door can be opened flexibly. The coal gate is easy to lift, and the thickness of the coal layer on both sides of the boiler grate is the same. If the distances are not equal, adjust them using the adjustment bolts to make them equal. The cover plate on the coal gate should be tightly covered to prevent coal from leaking in and blocking the upward and downward movement of the coal gate.